Español

AV Block on the ECG: First, Second and Third Degree

By Francisco Rodríguez Caamaño · Nurse · Cardiology and Coronary Care

You don’t understand AV blocks by counting QRS complexes: you understand them by following P waves. The central question is simple: does every atrial activation manage to produce a ventricular complex?

First degree: they all conduct, but late. Second degree: some don’t conduct. Third degree: there’s no repeating AV relationship.

Atrioventricular (AV) block occurs when conduction of the impulse from the atria to the ventricles is delayed or fails. To interpret it we need to follow two clocks separately:

  • the atrial clock, marked by the P waves;
  • the ventricular clock, marked by the QRS complexes.

This page puts the main degrees in a single sequence so you can compare first degree, Mobitz I, Mobitz II, 2:1 block, advanced block and complete AV block without memorizing six separate patterns.

How to analyze any AV block

  1. Identify every P wave, including any that may be hidden in the T wave or QRS.
  2. Check whether the PP intervals keep a steady pace.
  3. Decide how many P waves manage to produce a QRS.
  4. Measure several PR intervals, not just one.
  5. If a P wave doesn’t conduct, check whether it arrived on time.
  6. Separate 2:1 conduction from Mobitz I and Mobitz II.
  7. Look for two or more consecutive blocked P waves.
  8. If it looks like complete block, calculate the atrial and ventricular rates separately.
  9. Describe the width and rate of the escape rhythm.
  10. Extend the strip if the relationships could be mere coincidences.
Comparison of first-degree AV block, Wenckebach, Mobitz II, 2:1 block, advanced block and complete block
Figure 12.1 from El idioma del ECG (in Spanish): comparison of first-degree AV block, Wenckebach, Mobitz II, 2:1 block, advanced block and complete block (labels in Spanish). Tap the image to see it full size.

First-degree AV block

In first-degree AV block , all P waves conduct, but the PR interval is prolonged:

One P wave for every QRS + PR >200 ms and constant.

No QRS is dropped. That’s why the term “block” can be misleading: on the ECG we’re seeing a delay in AV conduction.

Before measuring, find the start of the P wave and the start of the QRS carefully. A very long PR can put the P wave close to the previous T wave and make it look disconnected from the next complex.

Second-degree AV block

In second degree, some P waves don’t produce a QRS. To classify the pattern, you need to look at what the PR was doing before the dropped beat.

Mobitz I or Wenckebach

The classic pattern shows a progressive worsening of conduction within a group:

PR gets longer → a nonconducted P wave appears → the cycle restarts with a shorter PR.

The QRS complexes usually appear in groups. The ratio can be described as 4:3, 3:2 or 5:4: the first number is the P waves and the second the QRS complexes.

The blocked P wave should appear at the expected time according to the atrial pace. If it comes early and distorts the T wave, think first of a blocked premature atrial complex.

Mobitz II

In Mobitz II, the PR intervals of the conducted beats stay similar, and a P wave that arrives on time is blocked with no progressive lengthening beforehand:

Stable PR → nonconducted P wave → stable PR.

To support this classification you have to show a reasonably stable atrial pace and several comparable conducted PR intervals. A blocked premature P wave or a simultaneous change in sinus rhythm can mimic the pattern.

A wide QRS or an associated bundle branch block may point toward infranodal disease, but it doesn’t define Mobitz II on its own. The classification depends on how the PR behaves.

2:1 AV block: don’t call it Mobitz I or II by reflex

With 2:1conduction, one P wave conducts and the next one doesn’t. We only have one useful PR before each dropped beat, so we can’t watch a lengthening sequence or show that several consecutive PR intervals are constant.

The most rigorous description is: second-degree AV block with 2:1 conduction.

The QRS, the context, rate changes or longer recordings may point to the level of the block, but a single strip doesn’t justify forcing the subtype.

Advanced or high-grade AV block

When two or more consecutive P waves don’t conduct, we call it advanced or high-grade AV block. Ratios of 3:1, 4:1 or higher may be seen.

What matters is that some conduction can still be shown. Certain QRS complexes appear after a P wave with a repeated PR or within a recognizable ratio.

Don’t use a 3:1 or 4:1 ratio as an automatic example of Mobitz II: with so few conducted beats it may be impossible to know whether the mechanism is type I or II.

Third-degree or complete AV block

In complete AV block , conduction from the atria to the ventricles can’t be shown. The P waves keep one pace and the QRS complexes another, sustained by an escape rhythm.

  • The P waves may be regular.
  • The QRS complexes may also be regular, but at a different rate.
  • The apparent PR intervals keep changing.
  • P waves can fall before, inside or after the QRS and T wave.
  • The atrial rate is usually faster than the ventricular rate.

A P wave can land just in front of a QRS by chance. True conduction must repeat with a consistent timing relationship. If the two sequences cross over and the PR intervals change, that coincidence doesn’t prove conduction.

Junctional or ventricular escape in complete block

When no P wave conducts, another pacemaker has to keep the ventricles going.

EscapeQRSApproximate rate
JunctionalUsually narrow, unless there’s preexisting aberrancyGenerally faster
VentricularUsually wideGenerally slower

The escape morphology adds context, but the diagnosis of complete block depends on showing that the atria and ventricles are independent.

AV dissociation doesn’t automatically mean complete block

Atrioventricular dissociation means the P waves and QRS complexes move independently. It can also appear when a junctional or ventricular rhythm speeds up and overtakes a slower sinus node.

Every complete AV block produces AV dissociation, but not every AV dissociation is complete AV block.

In complete block, atrial activity is usually faster and no impulse can be shown to conduct to the ventricles.

How to tell AV block from a sinus pause

When a QRS is missing, first look for the P wave that should have appeared. This same logic links AV block to our article on sinus pause.

During the pauseWhat you should consider
The expected P wave doesn’t appearSinus pause or sinoatrial exit block
A P wave appears on time and there’s no QRSAV block
An early P wave distorts the T wave and doesn’t conductBlocked premature atrial complex
A late QRS appears with no related preceding P waveEscape beat
P waves and QRS complexes keep independent pacesAV dissociation

Quick comparison of AV blocks

PatternP waves that conductPRKey
First degreeAllLong and constantNo QRS is dropped
Mobitz ISomeGets longer before the dropped beatWenckebach
Mobitz IISomeConstant before and afterFailure with no progression
2:1One in twoCan’t be classifiedOnly one useful PR per cycle
AdvancedFew conductSometimes hard to assessTwo or more P waves blocked in a row
CompleteNo relationship can be shownVaries by chanceAV dissociation

Common mistakes when interpreting AV block

  • Calling any bradycardia AV block.
  • Measuring a single PR and classifying the whole tracing.
  • Mistaking a blocked premature atrial complex for Mobitz II.
  • Calling 2:1 conduction Mobitz II.
  • Using a wide QRS as a diagnostic criterion for Mobitz II.
  • Calling any AV dissociation complete block.
  • Looking only for irregularity: complete block can show P waves and QRS complexes that are each regular on their own.

How to write the conclusion

  • “Sinus rhythm with first-degree AV block, PR of 240 ms and a narrow QRS.”
  • “Second-degree AV block type I with 4:3 Wenckebach periods.”
  • “Second-degree AV block type II, with intermittent loss of conduction.”
  • “Second-degree AV block with 2:1 conduction, not classifiable as type I or II on this strip.”
  • “Advanced AV block with 3:1 conduction.”
  • “Complete AV block with a wide ventricular escape rhythm at about 32 bpm and AV dissociation.”

Frequently asked questions about AV block on the ECG

Does first-degree AV block drop QRS complexes?

No. Every P wave conducts; the PR is simply prolonged beyond 200 ms.

How do I tell Mobitz I from Mobitz II?

In Mobitz I, the PR gets progressively longer before a nonconducted P wave. In Mobitz II, the conducted PR intervals stay similar and the dropped beat appears with no prior progression.

Is a 2:1 block Mobitz II?

Not necessarily. With one P wave conducted and the next one blocked, we don’t have several consecutive PR intervals to show lengthening or constancy. It should be described as 2:1 AV block if the strip offers no more information.

Are complete AV block and AV dissociation the same thing?

No. Complete block produces AV dissociation, but dissociation can also appear when a junctional or ventricular rhythm overtakes a slower atrial rhythm.

To follow the journey step by step, you can go back to atrial flutter on the ECG or continue with bundle branch blocks on the ECG.

References

Last editorial and scientific review: November 22, 2026 · About the project

Educational note. Content aimed mainly at students and healthcare professionals. ECG interpretation must always be integrated with the clinical situation.

Practice with a tracing: Follow the P waves and compare the different degrees of AV block in the online ECG generator.

In the course you can practice, in order, first-degree AV block, second-degree AV block and complete AV block.

If you read Spanish, the complete guide to reading any ECG with the eight-step method is in “El idioma del ECG”.

Rate this article No ratings yet
Views: 0

About the author

Francisco Rodríguez Caamaño is a nurse (Diploma in Nursing, University of Salamanca, 1998) who currently works in cardiology and the coronary care unit. He created Cardiología sin Miedo, an educational project that explains cardiology and electrocardiography with clarity, reasoning and rigor.

You can keep going with the map of ECG articles by topic or practice right away with the ECG generator.

Leave a Reply