Español

Basic ECG Course. Lesson 9. Electrical Axis with I and aVF

The electrical axis tends to intimidate people because it’s taught as a circle full of degrees. For a basic reading we can start much more simply: by looking at I and aVF.

There’s only one combination where we’ll need a third lead: II.

I + aVF first. II only if you need it.

By the end of this lesson you should be able to

  • Explain what the QRS axis represents.
  • Remember that it’s calculated in the frontal plane.
  • Decide whether a QRS is net positive, net negative or equiphasic.
  • Classify the axis with I and aVF.
  • Use II when I is positive and aVF is negative.
  • Recognize a normal axis, left axis deviation, right axis deviation and extreme axis.
  • Know that a nearly isoelectric lead can be used to fine-tune the axis, without needing to master that second level in Fundamentals.
  • Check whether the automated axis matches the tracing.

1. What the QRS axis really is

During the QRS, millions of ventricular cells depolarize and generate electrical forces that change continuously. If we sum up that whole process as one average dominant direction, we get the electrical axis of the QRS.

  • It isn’t a new wave.
  • It doesn’t measure contractile force.
  • It doesn’t describe every instant of the QRS.
  • It describes where ventricular depolarization points, overall.

In this lesson we’re talking about the QRS axis.

2. Bring back an idea you already know

In the lesson on leads we learned:

  • if an electrical force heads toward a lead’s positive pole, the deflection tends to be positive;
  • if it heads away, it tends to be negative;
  • if it runs nearly perpendicular, it may be small or equiphasic.

The axis doesn’t add a new idea. We simply use the leads as observers that tell us which way ventricular activation points.

Electrical vector and lead: positive, negative or isoelectric deflection
Before classifying the axis, you need to be able to decide whether a QRS is positive, negative or equiphasic overall. Tap to enlarge.

3. The axis is calculated in the frontal plane

We work with the limb leads:

I, II, III, aVR, aVL and aVF.

V1–V6 belong to the horizontal plane and aren’t the main players in this calculation.

Hexaxial reference system of the frontal plane leads
Hexaxial system of the frontal plane. For the basic method you don’t need to memorize every angle. Figure from El idioma del ECG. Tap to enlarge.

4. First decide whether the QRS is positive or negative

It isn’t enough to ask whether there’s an R wave. Look at the overall balance of the QRS.

  • Net positive QRS: the part above the isoelectric line dominates.
  • Net negative QRS: the part below dominates.
  • Equiphasic or nearly isoelectric: both parts are similar.

A small R wave followed by a deep S wave is still a net negative complex.

Don’t count letters. Look at which side the complex leans toward.

5. I and aVF: a compass

Lead I looks mainly to the left. aVF looks downward.

We ask:

  • Does the QRS point to the left? → I.
  • Does the QRS point downward? → aVF.
IaVFDirectionBasic classification
++Down and leftNormal
−+Down and rightRight axis deviation
−−Up and rightExtreme axis
+−Up and leftCheck II

6. Positive I + positive aVF: normal axis

A positive lead I means the dominant direction points to the left. A positive aVF means it also points downward.

That corresponds roughly to the range 0° to +90°, well within the normal axis.

The normal adult range extends a bit further to the left, to about −30°. That small extension is why one combination requires checking II.

7. Negative I + positive aVF: right axis deviation

Negative I: the vector moves away from the left and points more to the right. Positive aVF: it still points downward.

Right + down → right axis deviation.

8. Negative I + negative aVF: extreme axis

If both are negative, the dominant direction moves away from both I and aVF and points overall up and to the right.

Up + right → extreme axis.

9. Positive I + negative aVF: this is where II comes in

This is the only combination in the basic method that we can’t classify with two leads.

Positive I and negative aVF put the axis in the upper left quadrant. It may still be between 0° and −30°, which is within the normal adult range, or it may have moved further to the left.

  • Positive II: roughly 0° to −30° → still normal.
  • Negative II: beyond roughly −30° → left axis deviation.

I + / aVF − → ask lead II.

10. The complete compass

  • I + / aVF + → normal.
  • I − / aVF + → right axis deviation.
  • I − / aVF − → extreme axis.
  • I + / aVF − → check II: II + normal; II − left axis deviation.

That’s the method you need to master for the basic course.

Going further · optional. The I + aVF method, plus lead II when needed, is enough to classify the axis in this course. The most isoelectric lead lets you fine-tune the angle, but you don’t need to master that second level to pass Fundamentals.

11. What if the QRS is nearly isoelectric?

Real ECGs don’t always give you clearly positive or negative complexes. If the positive and negative parts are almost equal, the complex may be equiphasic.

In that case, don’t force a classification. If we need to fine-tune, we can look for the most isoelectric lead: the axis will be roughly perpendicular to it.

Example: aVL is nearly isoelectric. aVL points to about −30°. Its perpendiculars are around +60° and −120°. If I, II and aVF are positive, the direction that fits is close to +60°.

This second level is for fine-tuning. For most ECGs in the basic course, classifying the axis correctly will be enough.

12. The axis describes; it doesn’t diagnose

Finding left or right axis deviation doesn’t, on its own, tell us what disease the patient has.

The axis can shift for many reasons: anatomical orientation, hypertrophy, conduction disorders, scars or certain rhythms. Its meaning is interpreted together with the rest of the ECG and the context.

13. Check the automated axis

The electrocardiograph may print, for example, “QRS axis +47°”. We can use that number, but now we know how to check whether it makes sense.

+47° should match a positive I and a positive aVF. If the machine reports +140° and we see both clearly positive, something doesn’t add up.

Then we review the tracing, the calculation and the technique. In particular, remember that reversed arm electrodes can change the frontal plane leads dramatically.

14. Put it all together

ECG at 25 mm/s. Regular RR intervals. Four large boxes between R waves. Organized P waves, positive in II and negative in aVR. Positive I and positive aVF.

  • Ventricular rate: 75 bpm.
  • Regularity: regular.
  • Atrial activity: consistent with a sinus origin.
  • Axis: normal.

A few lessons ago we only saw lines. Now we can describe rate, regularity, origin and axis in an orderly way.

15. Practice

Negative I and positive aVF. What’s the axis?

Show solution

Right axis deviation.

Negative I and negative aVF. What’s the axis?

Show solution

Extreme axis.

Positive I and negative aVF. Can you answer yet?

Show solution

No. You need to check II. If II is positive, it’s still in the normal range; if it’s negative, it’s left axis deviation.

16. Check what you’ve learned

1. What does the QRS axis describe?
2. Positive I and positive aVF:
3. Negative I and positive aVF:
4. Negative I and negative aVF:
5. Positive I and negative aVF: what do you do?
6. If I+, aVF− and II−:
7. A nearly equiphasic lead can be used…

17. Summary

  • The QRS axis describes an average direction of ventricular depolarization in the frontal plane.
  • First decide whether the QRS is net positive or net negative.
  • I + / aVF + → normal.
  • I − / aVF + → right.
  • I − / aVF − → extreme.
  • I + / aVF − → check II.
  • II + → still normal; II − → left axis deviation.
  • The isoelectric lead is for fine-tuning, not for complicating the first step.
  • The axis describes; it doesn’t diagnose on its own.

Video for this lesson

Coming soon. The video lesson will be published on YouTube (in Spanish) and embedded here.

Sources and criteria for Block 1