The course is designed for adults who are new to ECG interpretation. That’s why it uses practical, deliberately simplified criteria when a more detailed classification adds nothing at this stage. Pediatric variants, advanced diagnostic criteria and specific exceptions are covered in their own blocks.
Basic criteria used
- Standard recording: 25 mm/s and 10 mm/mV, unless stated otherwise.
- PR: a practical adult reference of 120–200 ms.
- QRS: usual duration up to about 110 ms; >110 and <120 ms, mildly prolonged; ≥120 ms, wide QRS.
- QRS axis: an approximate adult reference of −30° to +90°.
- QT/QTc: the QT is interpreted with heart rate and QRS duration in mind; the automated QTc should be checked when the tracing, the rate or the T-wave morphology make it doubtful.
- ST and T: described by position, shape, distribution and relationship to the QRS before a cause is assigned.
- Technique: interpretation starts by checking quality, speed, calibration, artifacts and plausible electrode placement.
Main references
- Kligfield P, Gettes LS, Bailey JJ, et al. Recommendations for the Standardization and Interpretation of the Electrocardiogram. Part I: The Electrocardiogram and Its Technology. Circulation. 2007;115:1306–1324.
- Surawicz B, Childers R, Deal BJ, Gettes LS. AHA/ACCF/HRS Recommendations for the Standardization and Interpretation of the Electrocardiogram. Part III: Intraventricular Conduction Disturbances. Circulation. 2009;119:e235–e240.
- Rautaharju PM, Surawicz B, Gettes LS, et al. AHA/ACCF/HRS Recommendations for the Standardization and Interpretation of the Electrocardiogram. Part IV: The ST Segment, T and U Waves, and the QT Interval. Circulation. 2009;119:e241–e250.
- El idioma del ECG. Cardiología sin Miedo (in Spanish). Part I: fundamentals, the grid, electrodes, waves and intervals, rate, rhythm, axis and a systematic reading method.
How the course uses these sources
The references aren’t used to turn each lesson into a consensus document. Their job is to set a reliable technical floor. The content is then reorganized with a teaching goal: understand first, measure next and integrate at the end.
When there’s more than one valid way to state a criterion, the course picks the one that’s clearest for a beginner without losing clinical accuracy.