Basic ECG Course. Lesson 7. Measuring P, PR, QRS, QT and QTc
Counting boxes is easy. Measuring an ECG well isn’t about counting: it’s about deciding exactly where the thing you want to measure starts and ends.
Two people can use the same tracing, both know that each small box equals 40 ms, and still get different results if they put the start or end of a wave in different places. That’s why we’ll always use the same routine.
Identify → mark the boundaries → measure → check that it makes sense.
By the end of this lesson you should be able to
- Check speed and calibration before measuring.
- Measure the duration and amplitude of the P wave.
- Measure the PR interval correctly.
- Mark out the duration of the QRS.
- Identify the start and end of the QT.
- Recognize the tangent method as an optional tool when the end of the T wave is unclear.
- Understand what the QTc tries to correct.
- Recognize when an automated measurement should be checked.
1. Before measuring, check the ruler
Everything from Lesson 3 still applies. Before you place a single measurement on the tracing, check:
- Speed: usually 25 mm/s.
- Gain: usually 10 mm/mV.
- Quality: a reasonably stable baseline and identifiable waves.
At 25 mm/s, one small box represents 40 ms. At a calibration of 10 mm/mV, 1 vertical mm represents 0.1 mV. If those settings change, our ruler changes too.

2. The P wave: measure the whole wave
P wave duration is measured from the first point where it clearly leaves the baseline to the point where it returns to it.
We don’t measure from the peak. We measure the whole wave.
Example: a P wave takes up 2.5 small boxes.
2.5 × 40 ms = 100 ms.
As a practical reference in adults, P wave duration is usually <120 ms, that is, less than three small boxes at 25 mm/s.
We can also measure its amplitude from the baseline to the peak. At standard calibration, 2 mm equals 0.2 mV. In lead II, a positive P wave taller than about 2.5 mm is considered increased.
Lead II usually shows the P wave well, but you don’t have to measure it there. If its boundaries are clearer in another lead, use the one where you can mark them most clearly.
3. The PR interval: from the start of P to the start of the QRS
Let’s bring back a distinction from Lesson 6: we don’t measure the PR segment; we measure the PR interval.
- Start: the first point of the P wave.
- End: the first point of the QRS.
If it takes up four small boxes:
4 × 40 ms = 160 ms.
The usual adult reference is about 120–200 ms, between three and five small boxes at standard speed.
The PR isn’t simply “the time spent in the AV node”. It includes atrial depolarization and conduction up to the start of ventricular activation.
Besides how long it is, get used to checking whether it stays the same from beat to beat. What its variations mean comes later, in the conduction block.
4. The QRS: where it starts and where it ends
We measure from the first deflection that starts ventricular activation to the end of the last fast deflection, where we reach the J point.
A QRS of 2.5 small boxes:
2.5 × 40 ms = 100 ms.
As a practical reference in adults:
- ≤110 ms: usual duration.
- >110 and <120 ms: mild prolongation.
- ≥120 ms: we usually call it a wide QRS.
So “under 120 ms” doesn’t automatically mean “completely normal”.
On a 12-lead ECG, the start of the QRS may show up earlier in one lead and the end later in another. That’s why the true duration is a global measurement: from the earliest ventricular onset to the latest end you can identify across the leads. In practice, look at several leads and don’t just pick the one where the complex looks narrowest.
5. ST and T: not everything should become a number
To assess the ST segment, we need to locate the J point accurately and have a reliable reference line. Then we can measure how far it departs from it.
But interpreting the ST segment doesn’t depend only on millimeters: shape, the leads involved and the context matter too. The same goes for the T wave. Its full clinical interpretation comes in Lesson 11.
6. The QT: the start is usually easy; the end of the T wave isn’t always
- Start of the QT: start of the QRS.
- End of the QT: end of the T wave.
The problem is usually pinpointing where the T wave ends. It doesn’t end at its peak; it ends when visible repolarization returns to the baseline.
Going further · optional. If the end of the T wave is clear, you don’t need this tool. The tangent method makes an uncertain end-of-T measurement more reproducible.
The tangent method
When the terminal downslope of the T wave blends gradually into the baseline, we can use a reproducible rule:
- Find the steepest terminal slope of the T wave.
- Picture or draw a tangent along that slope.
- Take the point where that tangent crosses the baseline as the end of the T wave.
It doesn’t make a difficult wave mathematically perfect, but it reduces guesswork.
7. What to do if there’s a U wave
If the U wave is small and clearly separate, it isn’t included in the QT. The QT ends with the T wave.
If T and U are fused and you can’t tell where one ends and the other begins, don’t invent a precision the tracing doesn’t offer. Look for another lead where the end of the T wave is clearer.
Lead II and some lateral leads are often useful, but the priority is a well-defined QRS onset and T-wave end. For serial comparisons, try to use a comparable lead and method.
8. Why the corrected QT exists
The QT changes with heart rate: it usually shortens when the heart speeds up and lengthens when the rate slows.
That’s why we use the corrected QT, or QTc, which tries to estimate how we’d interpret that QT once the effect of heart rate is accounted for.
The best-known classic formula is Bazett’s:
QTc = QT / √RR
You don’t need to memorize it for this course. You do need to understand two things: the QTc is a mathematical correction, and no formula works perfectly at every heart rate.
Bazett’s formula, for example, tends to overestimate the QTc, especially at high heart rates. The automated value is useful, but not infallible.
9. When to check the automated QTc
- A small, biphasic or odd T wave, or one with an unclear end.
- A very fast or very slow heart rate.
- A very irregular rhythm.
- A U wave that could be mistaken for the end of the T wave.
- A very wide QRS.
- A result that doesn’t match what you see.
If the QTc is going to change an important decision, first check that the QT was measured correctly and, when it matters, which formula the machine used.
Going further · optional. This section introduces an important idea for avoiding QT errors when the QRS is very wide. You don’t need to calculate the JT interval or special corrections to pass this block; just remember that a wide QRS lengthens the QT too.
10. Long QT with a wide QRS: the number needs context
The QT starts at the beginning of the QRS. So the QRS itself is part of the QT.
If a patient has a QRS of 170 ms and a QTc of 510 ms, we shouldn’t read that 510 exactly as we would if the QRS were 90 ms. Part of the prolongation comes from a much longer ventricular depolarization.
For these situations there are tools such as the JT interval and specific corrections. We don’t need to calculate them here. The basic rule is enough:
Don’t interpret a QT without first checking how wide the QRS is.
11. Practical QTc reference values
As practical screening values in adults, it’s worth paying attention when the QTc is above roughly:
- 450 ms in men.
- 460 ms in women.
- Values around 500 ms or more deserve particular attention in the right context.
These are reference points, not diagnoses. A single QTc doesn’t diagnose long QT syndrome on its own. Measurement quality, heart rate, the QRS, medications, electrolytes, the clinical context and comparison with previous ECGs all matter.
12. The final measurement routine
| Measurement | Start | End | Basic reference |
|---|---|---|---|
| P | Start of P | End of P | <120 ms |
| PR | Start of P | Start of QRS | 120–200 ms |
| QRS | First ventricular deflection | J point | Usual ≤110 ms; wide ≥120 ms |
| QT | Start of QRS | End of T | Depends on heart rate |
| QTc | Correction of the QT | — | Interpret in context |
13. Practice
At 25 mm/s, a P wave takes up 2.5 small boxes. What’s its duration?
Show solution
2.5 × 40 = 100 ms.
The PR takes up 4 small boxes. What’s its duration?
Show solution
4 × 40 = 160 ms.
The QRS takes up 3 small boxes. Would you call it normal just because it “doesn’t go over 120”?
Show solution
No. 3 × 40 = 120 ms, the working threshold for a wide QRS.
The machine reports a QTc of 510 ms and the QRS measures 170 ms. What do you do before interpreting the number?
Show solution
Check the end of the T wave, the heart rate, the correction formula, any possible U wave and, above all, the width of the QRS.
14. Check what you’ve learned
The PR interval starts at the beginning of the P wave.
From 120 ms on, we usually use the term wide QRS.
The QT ends when the T wave ends, not at its peak or at the end of the U wave.
The QTc is a mathematical correction of the QT for heart rate.
Automated doesn’t mean infallible.
With a wide QRS, part of the QT prolongation comes from prolonged ventricular depolarization.
15. Summary
- Before measuring: speed, calibration and quality.
- P: start to end of P.
- PR: start of P to start of QRS.
- QRS: first to last ventricular deflection.
- QT: start of QRS to end of T.
- A clearly separate U wave isn’t included in the QT.
- The QTc tries to correct for the effect of heart rate.
- An important automated value should be checkable by eye.
Video for this lesson
Coming soon. The video lesson will be published on YouTube (in Spanish) and embedded here.
Course navigation
← Lesson 6. Waves, segments and intervals · Back to the course · Lesson 8. Heart rate, regularity and rhythm origin →