Low voltage and electrical alternans make a memorable pair, but they aren’t the same as cardiac tamponade. The ECG can suggest a large pericardial effusion; the hemodynamic impact belongs to the clinical picture and imaging.
The ECG can raise suspicion. It can’t measure the effusion or diagnose tamponade on its own.
In a pericardial effusion, the fluid surrounding the heart can change the amplitude and appearance of the tracing. The two classic findings are low QRS voltage and electrical alternans, often accompanied by sinus tachycardia. However, neither is constant and both have differential diagnoses.

What low voltage means on an ECG
At standard calibration of 10 mm/mV, low voltage is present when all QRS complexes measure less than 5 mm in the limb leads. Another criterion used is that all QRS complexes measure less than 10 mm in the precordial leads. Before applying it, check the calibration: a recording taken at half gain can mimic low voltage.
In a large effusion, the fluid and the effective distance between the heart and the electrodes can help reduce the recorded voltage. But low voltage is nonspecific and can appear with obesity, emphysema, hypothyroidism, infiltrative diseases, cardiomyopathies, anasarca and other settings.
Low voltage describes an amplitude. It doesn’t name a cause.
Electrical alternans: when the QRS changes from one beat to the next
Electrical alternans is a repeating, beat-to-beat variation in the amplitude or apparent axis of the QRS. In a large pericardial effusion it can reflect the heart swinging inside the fluid-filled pericardial sac: the heart slightly changes its orientation relative to the electrodes and the electrocardiograph records alternating complexes.
It’s a classic, striking finding, but it shouldn’t become a stand-alone diagnostic test. Not every effusion produces alternans, and not every alternans means an effusion. There are also forms of alternans related to tachycardias and other electrical mechanisms.
Sinus tachycardia completes the classic triad, but it’s still nonspecific
In patients with a large effusion or tamponade, sinus tachycardia can appear as a physiological response. The combination of tachycardia, low voltage and electrical alternans is well known, but it isn’t required. A patient can have a significant effusion without all three elements.
Pericardial effusion isn’t the same as tamponade
Pericardial effusion describes the buildup of fluid. Cardiac tamponade describes the hemodynamic impact that appears when intrapericardial pressure compromises chamber filling and cardiac output.
That’s why the ECG can’t answer the decisive question: “is this effusion causing tamponade?”. That assessment relies on the clinical situation and echocardiography, together with the rest of the available data. How fast the fluid builds up also matters: a relatively small volume that appears quickly may be tolerated worse than a much larger chronic effusion.
A normal ECG doesn’t rule out a large effusion
Neither low voltage nor electrical alternans is sensitive enough to rule out an effusion. Their absence doesn’t let you close the diagnosis. If the clinical picture suggests pericardial involvement, imaging is still the tool for assessing whether there’s fluid, how much and its impact.
How to read the tracing with the 8-step method
- Technique: confirm 25 mm/s, 10 mm/mV and no artificial reduction in gain.
- Rate, regularity and origin: in the example there’s sinus tachycardia at around 105 bpm.
- Axis: check whether the QRS direction changes in a repeating, alternating way.
- P and PR: identify sinus atrial activity and avoid mistaking low voltage for absent P waves.
- QRS and precordial leads: assess the overall amplitude and show the beat-to-beat alternans pattern.
- ST and T: look for associated changes without blaming any repolarization change on the effusion.
- QT/QTc: measure it if indicated and if the end of the T wave is well defined.
- Integration: sinus tachycardia with low voltage and electrical alternans; findings that may suggest a large pericardial effusion in the right context and must be correlated with imaging.
How to write it up without overstating certainty
A careful conclusion would be:
Sinus tachycardia with low-voltage QRS complexes and electrical alternans. In the right clinical context, assess for a large pericardial effusion with echocardiography; the ECG doesn’t confirm tamponade.
Other causes of low voltage worth remembering
- Obesity and more tissue in between.
- Emphysema/COPD.
- Hypothyroidism.
- Infiltrative diseases.
- Cardiomyopathies with loss of effective electrical mass.
- Generalized edema or anasarca.
- Technical problems with gain or electrode contact.
Common mistakes
- Diagnosing tamponade from low voltage.
- Diagnosing an effusion from electrical alternans without context or imaging.
- Not checking the ECG gain before measuring voltages.
- Confusing irregular alternation with respiratory variation or artifact.
- Ruling out an effusion because the ECG doesn’t show the classic triad.
- Trying to estimate the volume of the effusion from the QRS amplitude.
Chapter 18 of El idioma del ECG (in Spanish) stresses this same idea: recognize low voltage and alternans without turning them into automatic diagnoses.
Related articles
References
- El idioma del ECG (in Spanish). Cardiología sin Miedo. Chapter 18 (in Spanish).
- European Society of Cardiology. 2025 ESC Guidelines for the management of myocarditis and pericarditis.
- Shanker DA, Gaur A, Warriner D. Pericardial Effusion: Overview of Aetiology, Pathophysiology, Diagnosis, and Management. Cureus. 2025;17(9):e92177.
Last editorial and scientific review: November 22, 2026 · About the project
Educational note. Content aimed mainly at students and healthcare professionals. The presence and impact of a pericardial effusion require clinical integration and imaging; the ECG doesn’t diagnose tamponade on its own.


Leave a Reply