Not every fast ventricular rhythm is ventricular tachycardia. Accelerated idioventricular rhythm (AIVR) appears when a ventricular focus temporarily takes over at a rate close to the sinus rate, and the two pacemakers can compete.
AIVR: wide QRS complexes of ventricular origin, a rate of roughly 50–110 bpm and an onset or end that’s often gradual.
After studying ventricular fibrillation, we bring the rate down a lot. The ventricle is still producing the complexes, but now the problem isn’t an extreme tachycardia; it’s telling apart a ventricular escape, AIVR and a slow ventricular tachycardia.

What is accelerated idioventricular rhythm?
Accelerated idioventricular rhythm(AIVR) appears when a ventricular focus fires at a rate high enough to compete with the sinus node, but without necessarily reaching the usual rates of ventricular tachycardia.
The word accelerated can be misleading. It doesn’t mean “very fast”. It means the ventricular pacemaker is accelerated compared with the classic ventricular escape rhythm.
How to recognize AIVR on the ECG
- Wide QRS complexes, because activation starts in the ventricle and spreads outside the usual fast network.
- Ventricular rhythm generally regular or nearly regular.
- Rate of roughly 50–110 bpm.
- No sinus P wave triggering each QRS.
- Possible atrioventricular dissociation.
- Possible capture and fusion beats when the sinus and ventricular rhythms compete.
- Onset and end often gradual.
The rate helps, but it shouldn’t become a rigid border. The same range can overlap with a slow ventricular tachycardia or with a relatively slow sinus rhythm competing with the ventricular focus.
Idioventricular rhythm vs AIVR
Idioventricular escape rhythm is a rescue mechanism. It appears late, after a higher pacemaker has failed to generate or conduct an impulse on time.

| Rhythm | Approximate rate | Main clue |
|---|---|---|
| Idioventricular escape | 20–40 bpm | Appears after a pause as a rescue rhythm |
| AIVR | 50–110 bpm | Competes with the sinus rhythm; onset often gradual |
| Ventricular tachycardia | >100 bpm | The ventricle dominates; assess morphology and mechanism |
The ranges overlap. That’s why timing, the relationship with the sinus rhythm and the way it starts or stops tell you more than deciding the diagnosis from a number alone.
Capture and fusion: when two rhythms compete
During AIVR, the sinus node may keep firing. If a supraventricular impulse occasionally takes over the ventricles completely, a capture beat similar to the baseline QRS appears.
If the sinus and ventricular impulses activate the myocardium at the same time, a fusion beatappears, with an intermediate morphology. These signs help show that two pacemakers are competing.
AIVR and reperfusion
AIVR is often seen in the setting of myocardial reperfusion, although it isn’t exclusive to it. The ECG identifies the rhythm; its meaning has to be interpreted together with the clinical context and the other findings.
That’s why “AIVR = reperfusion” shouldn’t be used as an automatic equation. It can appear in other situations, and reperfusion doesn’t have to produce AIVR.
AIVR vs slow ventricular tachycardia
This is the most interesting border. A rate of 105 bpm could fall into either territory depending on the source and the context.
- A gradual onset and end favor AIVR.
- Competition with the sinus rhythm, with capture and fusion beats, favors AIVR.
- An abrupt start and a clearly dominant rhythm may favor VT.
- Structural heart disease and the morphology of the episode change the probability.
When the rates overlap, describe the tracing before forcing it across a numerical border.
Don’t confuse AIVR with PVCs
A premature ventricular complex (PVC) is early: it appears before the next expected beat. A ventricular escape beat appears late. In AIVR there’s a sequence of ventricular complexes competing with the underlying rhythm.
Timing keeps three consecutive wide QRS complexes from automatically becoming “VT”: first you need to show they’re ventricular and judge whether they’re really fast for the context.
A practical method for reading AIVR
- Confirm that the QRS complexes are wide.
- Calculate the rate over several cycles.
- Look for P waves even if they seem independent.
- Check the P–QRS relationship.
- Look for capture and fusion beats.
- Watch how the episode starts and ends.
- Compare with the baseline ECG.
- Put the rate together with the timing and the context.
How to write the conclusion
Accelerated idioventricular rhythm at about 78 bpm, with wide QRS complexes and fusion beats.
If the border with slow VT can’t be settled with the available recording, it’s better to say so than to fake a precision that doesn’t exist.
Frequently asked questions about AIVR
At what rate does AIVR occur?
As a guide, roughly between 50 and 110 bpm. Some sources use slightly different limits. The rate helps, but it has to be combined with the onset, the relationship with the sinus rhythm and the context.
Are AIVR and ventricular tachycardia the same thing?
No. Both are ventricular rhythms and their rates can overlap, but AIVR usually competes with the sinus rhythm and starts or stops gradually.
Does AIVR prove reperfusion?
Not on its own. It’s a classic setting where it can be seen, but the tracing has to be combined with the rest of the clinical information.
Related articles
References
- El idioma del ECG (in Spanish). Cardiología sin Miedo. Chapter 14: “When the ventricle takes over: ventricular rhythms and wide-QRS tachycardias” (in Spanish).
- StatPearls. Idioventricular Rhythm.
- Clínica Universidad de Navarra. Ventricular escape and accelerated idioventricular rhythm (in Spanish).
Last editorial and scientific review: November 22, 2026 · About the project
Educational note. Content aimed mainly at students and healthcare professionals. ECG interpretation must always be integrated with the clinical situation.
Practice with a tracing: Review this topic with a synthetic case, then check your reading in the online ECG generator.


Leave a Reply